Flat roof insulation
Flat roof waterproofing and flat roof thermal insulation can be solved in one step with sprayed foam. Closed cell roof insulation is unbeatable for modernizing old and new roofs.
Flat roof waterproofing:
Closed-cell foam + UV protection (polyurea)
Estimated daily progress:
With one team 250 m2 (3-5 cm)
Recommended thickness:
for waterproofing 3 cm, for thermal insulation min. 6 cm
Material density:
Closed cell with a body density of 45-55 kg/m3
Thermal and waterproofing in one step
A zártcellás poliuretán hab az egyetlen szigetelőanyag, amely egyszerre biztosít kiváló hő- és vízszigetelést. A leghatékonyabb megoldás elöregedett, beázó lapostetők felújítására – mindezt bontás nélkül. Nem kell elszállítani a régi szigetelőrétegeket, így a kivitelezés gyors és költséghatékony.
Seamless, walkable
The expanded foam insulation creates a completely seamless surface, which eliminates the possibility of leaks and thermal bridges. The rigid insulation layer is stable, walkable, and load-bearing in the long term. It flexibly follows the movements of the roof, so it does not separate from the surface.
Can be applied to any surface
Whether it is bitumen insulation, concrete slab or wooden roof structure, purfoam roof insulation always provides perfect adhesion. Thanks to its versatility, it is suitable for insulating almost any industrial or residential flat roof.
Protection from the sun
Since the expanded foam is not UV-resistant, it is important to properly protect the flat roof insulation on open surfaces. In such cases, we seal the insulation with a special, polyurea-based resin paint. If the flat roof is used as a terrace, this polyurea layer may be subject to wear, in which case it is worth protecting the expanded foam roof insulation from the harmful effects of the sun with concrete, paving slabs or a gravel bed.
Thickness
More than half of a building's heat loss is through the roof, which is why flat roof insulation is of paramount importance. An optimal 10 cm thick closed-cell PU foam insulation is equivalent to more than 20 cm thick traditional thermal insulation (cotton or EPS) based on the lambda value.
We are often contacted for just a few leaks, to waterproof a flat roof. In such cases, we apply the insulation in the thinnest possible thickness, 3 cm, using the technology.
Durability
Foam roof insulation a technology that has been used for 60 years. According to experts, the material can retain its effectiveness for up to 80 years. This requires a proper, maintained UV protective coating.
Are there any open questions? Click here to view the Frequently Asked Questions!
❌ Problems with traditional flat roof insulation
High heating and cooling costs
Poor thermal insulation = loss of money all year round.
Frequent leaks
Outdated, tar-based flat roof waterproofing no longer lasts.
Dampness, mold
Condensation on the ceiling can also pose a health risk.
Cracks, gaps
The insulation layers do not follow the movement of the roof, so they can crack over time.
A complex hierarchy full of potential errors
Traditional materials do not provide both thermal and waterproofing. Repairs are expensive and complicated.
✅ The solution: flat roof insulation with polyurethane foam
Twice as effective insulation
The closed-cell foam's λ = 0.023 W/mK value is unbeatable.
Complete watertightness from just 3 cm
Perfect flat roof waterproofing
Moisture resistance + breathable structure
Condensation stops, the building does not "suffocate".
Flexible, crack-free surface
Follows roof movement – no expansion gaps.
Simple, safe layering
No complicated structure, less room for error.
Can be done without demolition
Rólunk mondták
Flat roof references
Panel szigetelés
Panelház szigetelés – referencia és tanulságok egy valódi projektről A panel szigetelés napjainkban kiemelt figyelmet kap az energiahatékonyság és komfort növelése miatt. Sok társasház, panellakás tulajdonos keres optimális megoldást – legyen szó panelház...
Lemezes pvc szigetelés javítása purhabbal
Fólia szigetelés javítása, lemezes szigetelés javítása Egy nagykereskedés lapostetőjén végeztünk teljes fóliaszigetelés-javítást, ahol az elöregedett PVC lemezes szigetelés már komoly gondokat okozott. A tető több helyen megsüllyedt, beázott, a víz pangott a...
PVC roof repair
Foamed solution for repairing PVC roofs – thermal and waterproofing in one step Why did it become necessary to repair the PVC roof? In Budapest, the old roof insulation caused serious problems at the industrial hall located next to Egérút. The aged layer no longer excluded...
Vecsés insulation – Anvil insulation
Anvil insulation, workshop insulation Flat roof renovation with foam - questions and answers Why is flat roof renovation important? Flat roofs are among the structural parts most exposed to the weather. Aged bituminous sheets and gravel insulation are often...
Tar roof insulation
Tar roof insulation in Sátoraljaújhely – 2000 m² production hall reference work Our latest work was carried out in Sátoraljaújhely, where we had to modernize the insulation of a nearly 2000 m² tar roof. The client's goal was to achieve a durable and effective thermal insulation...
Why is expanded foam better than bitumen insulation?
100 m² flat roof insulation with polyurethane foam – in Cegléd quickly, permanently, without demolition Insulating a 100 m² flat roof is a serious decision, especially if the roof is covered with an old, aged bitumen layer. Fortunately, there is now a modern solution that does not...
Other applications
Request an offer!
Euro-Ker-Szig Kft.
4251 Hajdúsámson
Debreceni út 24















